Skip to content

Linux Installation

This guide describes the distribution material and how to install, license and verify SHIPFLOW — the flow solver, the SHIPFLOW GUI and the post-processor — on workstations and computers running Linux. For Windows, see Windows Installation.

Distribution material

SHIPFLOW for Linux is delivered as one compressed archive that contains the complete installation directory: the GUI, the mesh generators, the solvers, the examples and the documentation, including the Release Notes for all versions.

Download from the FLOWTECH Support page

Download the installation archive from the FLOWTECH Support page at flowtech.se. To get a user id and a password for the Support page, contact [email protected]. The Support page explains how to download the software. Then continue with Install SHIPFLOW.

Distribution on CD-ROM

The installation archive can also be supplied on a CD-ROM.

Documentation

The documentation is installed as PDF files in the doc directory. The User's Manual, the Examples Manual and the instructions for remote computations are also available on this site, see User Manuals and Examples Manual.

Installation directory

The archive unpacks into one SHIPFLOW root directory that contains both the flow solver and the post-processor. In SHIPFLOW 8.0.37, for example, the root directory shipflow8.0.37-linux-x86_64 contains these main directories:

shipflow8.0.37-linux-x86_64/
    bin/
    data/
    Framework/
    Framework5/
    paraview/
    paraview-osmesa/
    doc/
    examples/
    examples_motions/
    examples_waps/
    tutorials/
    lib/
        missing/
    lic/
    mpi/

In this guide, shipflow/ stands for the SHIPFLOW root directory. In commands, it is written as <full_path>/shipflow<version>: replace this with the full path of your root directory, for example /opt/shipflow8.0.37-linux-x86_64.

bin directory

File Description
shipflow Script that starts SHIPFLOW. It also sets OpenMP defaults for the solvers when you have not set them yourself: OMP_PROC_BIND=spread, OMP_PLACES=cores, and on EPYC and Xeon processors OMP_WAIT_POLICY=passive with KMP_BLOCKTIME=0 (OMP_WAIT_POLICY=active on other processors). Your own values of these variables are kept.
shipflow_motions.env Environment overrides that apply only to the MOTIONS solver process, one NAME=VALUE entry per line; NAME= unsets a variable. As delivered it sets OMP_WAIT_POLICY=active and unsets KMP_BLOCKTIME. Leave the file empty to run MOTIONS with the unchanged SHIPFLOW environment.
shipflow_gui Script that starts the graphical user interface in the Framework directory.
shipflow_gui5 Script that starts the graphical user interface in the Framework5 directory.
pvpost Script that runs ParaView for the automatic reporting, see ParaView.
rshipflow.sh Script for remote computations.
Release Release information.

The directory also contains the executables of the SHIPFLOW modules.

data directory

File Description
non_bf_vg.fmt Data for the vortex generator object.
plots.tmpl Template file for the report generation.
propellers/ Propeller geometry files. SHIPFLOW looks here for a GEOFILE that is not in your working directory.
python_post_scripts/ Python scripts for the customisable automatic post-processing: scriptable plots with Python and ParaView.

Framework directory

This directory contains the user interface for SHIPFLOW with the Design/GUI add-ons. Start it with the shipflow_gui script in shipflow/bin.

Framework5 directory

This directory contains a second version of the user interface. Start it with the shipflow_gui5 script in shipflow/bin.

ParaView directories

The directories paraview and paraview-osmesa contain ParaView, which is used for some of the post-processing. See ParaView.

doc directory

This directory contains the documentation for SHIPFLOW as PDF files.

File Description
BendingMoments with Shipflow.pdf Describes the Python script that extracts the vertical and horizontal bending moments, the shear forces and the torsional moment.
ExamplesManual.pdf SHIPFLOW Examples Manual, also on this site as the Examples Manual.
InstallationNotesLinux.pdf SHIPFLOW Installation Notes for Linux — the PDF version of this guide.
InstallationNotesWindows.pdf SHIPFLOW Installation Notes for Windows, also on this site as Windows Installation.
ReleaseNotes.pdf SHIPFLOW Release Notes.
RemoteComputation.pdf Instructions for remote computations, also on this site as Remote computations.
UsersManual.pdf SHIPFLOW User's Manual, also on this site as the User Manual — Basic & RANS.
UsersManualMotions.pdf MOTIONS User's Manual.
XchapTheoreticalManual.pdf XCHAP Theoretical Manual.

examples directory

This directory contains all the input files, and some of the output files, for XPAN, XBOUND and XCHAP for the examples in the SHIPFLOW Examples Manual. It also contains the test examples used to verify the installation.

examples_motions directory

This directory contains all the input files for MOTIONS.

examples_waps directory

This directory contains demonstration examples for ships equipped with wind-assisted propulsion systems (WAPS), including manoeuvring simulations. The README.txt file in an example folder lists the steps to run it.

tutorials directory

This directory contains the SHIPFLOW tutorials as PDF files. The tutorials are also available on this site, starting with Basic Tutorial 1 and Advanced Tutorial 1.

lib directory

This directory contains dynamically linked libraries.

The subdirectory lib/missing may contain additional dynamic libraries that SHIPFLOW needs to start and that are missing on some Linux installations. If a library is missing on your system, move it from shipflow/lib/missing to shipflow/lib.

lic directory

This directory contains the licensing tools, packed in shipflow_lic.tgz. For node-locked licenses, we recommend that you unpack shipflow_lic.tgz in /usr/local for semi-automatic handling of the licensing, see Node-locked license.

mpi directory

This directory contains OpenMPI with thread support, which XCHAP uses. For most Linux versions it is hard to find a pre-compiled OpenMPI with thread support, so it is included with SHIPFLOW. Install it under /opt/local as described in OpenMPI; it then ends up in /opt/local/shipflow7. The file README.txt in this directory contains the same installation instructions.

Install SHIPFLOW

  1. Download the installation archive from the FLOWTECH Support page at flowtech.se. Contact [email protected] for a user id and a password for the Support page. The archive has the generic name shipflow<version>-<platform>.tgz.
  2. Move the archive to the directory that should contain the SHIPFLOW installation, for example /opt. The archive unpacks into a new SHIPFLOW root directory in the current directory.
  3. Change to that directory and unpack the archive:

    cd /opt
    tar xzf shipflow<version>-<platform>.tgz
    

    This creates the SHIPFLOW root directory, for example shipflow8.0.37-linux-x86_64.

  4. Install OpenMPI for XCHAP, see OpenMPI.

  5. Set up your license, see Licensing.
  6. Add shipflow/bin to your PATH, see PATH.
  7. Verify the installation.

OpenMPI

XCHAP uses OpenMPI with thread support. Thread support is in general not included in OpenMPI packages, so SHIPFLOW includes a package with thread support in shipflow/mpi. SHIPFLOW requires this package in /opt/local/shipflow7. You need root permissions to install in /opt.

  1. As root, change to /opt/local:

    cd /opt/local
    
  2. Unpack the OpenMPI package from your SHIPFLOW installation:

    tar xzf <full_path>/shipflow<version>/mpi/openmpi-shipflow7-Linux64.tgz
    

    This creates /opt/local/shipflow7.

This OpenMPI version will probably not work on all Linux distributions. If you run into a problem, contact [email protected].

Licensing

The licensing system described here has been used since SHIPFLOW 6.4. The licensing tools are delivered in shipflow/lic/shipflow_lic.tgz, which unpacks into a folder shipflow_lic. Follow the instructions for your license type:

License type What you set up
Node-locked Registration and activation on the computer that runs SHIPFLOW, see Node-locked license.
Network A license server, and on each client computer the SG_LICENSE_FILE variable and a license file network.lic.
Floating A license server, and on each client computer the SG_LICENSE_FILE variable.

If you are not sure which type of license you have, contact [email protected]. The license manager programs are described in Appendix A: License manager applications.

Node-locked license

First installation on a computer

  1. Copy the license tools to /usr/local and unpack them there:

    cp <full_path>/shipflow<version>/lic/shipflow_lic.tgz /usr/local
    cd /usr/local
    tar xzf shipflow_lic.tgz
    

    This creates the folder /usr/local/shipflow_lic.

    Note

    You can unpack the license tools in a different location, but SHIPFLOW then cannot activate licenses over the internet or start and restart the license server automatically when necessary.

  2. Register the computer by running the license script:

    cd /usr/local/shipflow_lic
    ./license
    

    When you register, make sure that you enter the correct email address: this is how we contact you when your license is ready for activation.

  3. Wait until you receive our email. If the license tools are in /usr/local/shipflow_lic, you are done: continue with Verify the installation.

  4. If the license tools are in a different location, activate your license by running ./license again.

Reinstalling or upgrading SHIPFLOW

If SHIPFLOW has been installed on the computer before:

  • If you have internet access and the license tools are in /usr/local/shipflow_lic, activation is automatic. Continue with Verify the installation.
  • If the computer has no internet connection and you need a new license file, send an email to [email protected].
  • If the license tools are not in /usr/local/shipflow_lic and you need a new license file, run the script ./license.

Manual commands

Run these scripts in the shipflow_lic folder. You will normally not need them if the licensing tools are in /usr/local/shipflow_lic.

To Run
Activate a new license over the internet (this also starts or restarts the license server) ./license
Start the license server, for example after the computer has been rebooted ./start_server
Restart the license server, for example after you have received a new license file by email ./restart_server

Network and floating licenses

Network and floating licenses both use a license server. In addition, a network license needs a license file on each client computer.

Floating and classroom licenses that were locked to a range of IP addresses in earlier versions are now called network licenses.

License server

Do the following on the computer that runs the license server for a network or floating license.

Note

The license server does not run on a virtual machine.

Install the licensing tools

Take the file shipflow/lic/shipflow_lic.tgz from a complete SHIPFLOW installation and unpack it in the location you prefer:

tar xzf shipflow_lic.tgz

This creates the folder shipflow_lic.

Activate the license

By default, the license server uses port 29750. If you want it to use a different port, tell us by email to [email protected].

On a computer with internet access

  1. In a terminal, change to the shipflow_lic folder and run ./license. We receive a notification that you have registered, and we get back to you once we have confirmed that you should have a license.
  2. When you have received our email that your SHIPFLOW license is activated on that computer, run ./license again. This downloads your license to the file shipflow.lic and starts the license server.

On a computer without internet access (or if our product activation server cannot be reached)

  1. In a terminal, change to the shipflow_lic folder and run ./license. This creates the file shipflow_lic.log.
  2. Send shipflow_lic.log to [email protected]. We reply with the license file.
  3. Save the license file as shipflow.lic in the shipflow_lic folder and run ./start_server.

Start the license server again

If you reboot the computer, or if the license server is stopped for some other reason, start it again with ./start_server in the shipflow_lic folder.

Obtain a new license file

You need a new license file when your license file expires or when you upgrade to a newer SHIPFLOW version.

  • With internet access: run ./license. This downloads your license to the file shipflow.lic and starts or restarts the license server.
  • Without internet access (or if our product activation server cannot be reached):
    1. Request the license file from [email protected].
    2. Save it as shipflow.lic in the shipflow_lic folder.
    3. If the license server is already running, run ./restart_server. If it is not running, run ./start_server.

Client computers

Do the following on each computer that will run SHIPFLOW with a network or floating license.

  1. Set the environment variable SG_LICENSE_FILE to <port>@<host>, where <host> is the address of the computer that runs the license server and <port> is the port number that the license server uses (29750 by default).
  2. Network license only:
    1. Send the range of IP addresses of the client computers to [email protected]. Use one or two wildcards, for example 192.168.1.* or 194.185.*.*. We reply with the license file.
    2. Save the license file as network.lic in /usr/local/shipflow_lic/. To keep network.lic in a different folder, set the environment variable SG_LICENSE_FILE_PATH to that folder, for example /home/<user>/lic/.

Environment variables

All required environment variables are set automatically when you start SHIPFLOW with the shipflow script. The variables below are the ones you might want to change for a particular installation.

PATH

To run SHIPFLOW, add the shipflow<version>/bin directory to the PATH environment variable. The command depends on your shell.

For the C shell:

set path=( $path <full_path>/shipflow<version>/bin )

Here <full_path> is the directory path from the root to shipflow<version>. For example, if SHIPFLOW 8.0.37 is installed under /opt, <full_path>/shipflow<version>/bin is /opt/shipflow8.0.37-linux-x86_64/bin. We recommend that you put this command in the .cshrc file of every user who will use SHIPFLOW.

For the Bourne shell (including bash) or the Korn shell, add this line to the user's .profile file:

PATH=$PATH:<full_path>/shipflow<version>/bin

SHIPFLOWMEM

SHIPFLOW uses dynamic memory allocation: storage for all vectors and arrays is allocated during execution in one global storage vector. SHIPFLOWMEM sets the size of this vector as a number of 4-byte words; for example, 64,000,000 corresponds to 256 MB of memory. If SHIPFLOWMEM is not set, the shipflow script sets it to 950000000.

To change the value in the C shell:

setenv SHIPFLOWMEM new_value

In the Bourne or Korn shell:

export SHIPFLOWMEM=new_value

We recommend that you specify SHIPFLOWMEM in .cshrc (C shell) or .profile (Bourne or Korn shell). You can also define it directly in the shipflow script in shipflow/bin.

If SHIPFLOWMEM is too small, SHIPFLOW stops and prints the required value in the id_OUTPUT file. Increase SHIPFLOWMEM to at least that value. See Memory errors for the upper limit and for what to check before you increase the value.

SG_LICENSE_FILE

Needed when the license server does not run on the same computer as SHIPFLOW. Set it to <port>@<host> of the license server, see Client computers.

In the C shell:

setenv SG_LICENSE_FILE <port>@<host>

In the Bourne or Korn shell:

export SG_LICENSE_FILE=<port>@<host>

SG_LICENSE_FILE_PATH

Optional, for network licenses: the folder that contains network.lic, if you keep it somewhere other than /usr/local/shipflow_lic/. See Client computers.

ParaView

ParaView is included with SHIPFLOW and is used to produce some of the plots in the automatic reporting. ParaView needs a graphical environment on the computer where SHIPFLOW runs:

  • If you run SHIPFLOW locally on your workstation, this is always available.
  • If you log in to a different computer, log in with the -X option.
  • If neither is possible (for instance on a cluster with a queueing system), the following is required:
    • Graphics hardware.
    • XDM must be installed and running. Ask your system administrators for help with this.
    • All security on the X server must be disabled, so that any process can open a window on the X server without logging in. Again, ask your system administrators for help. On some systems, the command xhost + does this.
    • Each pvbatch process must connect to the display localhost:0 (or just :0). Set this with the -display flag for pvbatch in the script shipflow/bin/pvpost.

In shipflow/bin/pvpost you can also add your own ParaView Python scripts to be used in the automatic reporting.

Verify the installation

  1. Check that the shipflow and shipflow_gui scripts in shipflow/bin are found from a command prompt, for example with which shipflow shipflow_gui. If they are not found, check the PATH environment variable.
  2. Create a test directory and change to it:

    mkdir test
    cd test
    
  3. Copy the test examples from the examples directory. The test command files read the offset file geometry/off_test, so copy that file into a geometry subdirectory:

    cp <full_path>/shipflow<version>/examples/test1 .
    cp <full_path>/shipflow<version>/examples/test2 .
    mkdir geometry
    cp <full_path>/shipflow<version>/examples/geometry/off_test geometry/
    
  4. Run the first test example, which tests the modules XMESH and XPAN:

    shipflow test1
    

    SHIPFLOW writes the files test1.cgns and test1_OUTPUT. If output for Tecplot is requested, it also writes files ending with .plt for post-processing with Tecplot.

  5. Look through test1_OUTPUT for warnings or error messages. If your examples directory contains a test1_OUTPUT file, compare your output with it.

  6. Run the second test example, which also runs the modules XBOUND, XGRID and XCHAP:

    shipflow test2
    

    Compare test2_OUTPUT in the same way. The computing time and memory requirements of test1 and test2 are moderate; each should complete within a few minutes.

The examples directory also contains a third test example, test3, a self-propulsion computation. Copy and run it in the same way if you want to test it too.

If a test does not run, check the following:

Problem What to do
No valid SHIPFLOW license can be checked out Check your license set-up, see Licensing.
Not enough memory Increase SHIPFLOWMEM to at least the value printed in the output file test1_OUTPUT, see SHIPFLOWMEM.

More problems and solutions are collected in Troubleshooting.

Appendix A: License manager applications

Applications

  • sglmserver — the actual license server. The client software communicates with it over the TCP/IP network protocol, whether the client runs on the same computer, on a local area network (LAN) or over the internet. The license server keeps track of the total number of licenses and how many remain for each licensed component. It uses a license file to control which components are valid, for how long, and how many licenses there are for each component.
  • sglmd — the license daemon. The license server can run on its own, but if the license daemon runs it, the daemon detects if anything happens to the license server and tries to restart it. This minimises the impact of an uncontrolled termination of the license server.
  • sglmutil — the license manager utility. It can shut down the license server and show which licenses the server has available.

These applications are in the shipflow_lic folder, together with the license, start_server and restart_server scripts.

Running the license server

The license server can be run in a terminal window, for testing or on a regular basis. With the optional -b flag it runs in the background. Because it can be useful to track the activity of the license server, you can specify a log file for all output from the server; this can also be /dev/null if you do not want any output.

The start_server script starts the license server in the background with sglmd, using the license file shipflow.lic and the log file debug.log. The restart_server script restarts it with sglmutil.

Limits

The license server supports a maximum of 64 components, 64 checked-out components per user, and 256 concurrent users, unless these limits are overridden at startup.

Command reference

sglmutil

sglmutil -c shutdown -f <license_file>
sglmutil -c restart -f <license_file>
sglmutil -c show -f <license_file>
Command Description
shutdown Shuts down the license server that runs the specified license file.
restart Restarts the license server that runs the specified license file.
show Shows which licenses are served by the license server of the specified file.

sglmd

sglmd {-b} -v <license_server> -f <license_file> {-d <debug_log_file>} {-m <max_connections>} {-x <csv_log_file>}

Uses the license daemon to start the license server with the licenses in the license file, and optionally writes the output to a log file.

  • -m <max_connections> overrides the default of 256 separate client applications that can connect to the license server. Each connection is a thread, so the practical maximum depends on your system configuration.
  • -b runs sglmd and sglmserver in the background.
  • -x <csv_log_file> writes a CSV log file that you can use to graph license usage over time — by user, component, version or any other criterion — with any graphing tool, for example Google Sheets.

sglmserver

sglmserver <license_file> {debug_log_file | null} {max_connections | null} {csv_log_file}

Starts the license server on its own, without automatic restart. Always use sglmd to control and start sglmserver, because sglmd makes sure that the server keeps running.

  • To specify max_connections without a debug log file, pass the string null as the second argument.
  • To specify csv_log_file without max_connections, pass the string null as the third argument.

The server license file

The license file contains a SERVER line with the computer name, the id that the license server is locked to, and the TCP/IP port number that client applications use to communicate with the server. It also contains a license count for each component. Example of a server license file:

SERVER=localhost ID=001f5bf5b08f IDTYPE=ethernet PORT=29750
NAME=tree VERS=4.0 ID=001f5bf5b08f IDTYPE=ethernet COUNT=12 EXPIRES=never CERT=e7fdb38c0e90c925c28368decf979e19
NAME=monkey VERS=4.0 ID=001f5bf5b08f IDTYPE=ethernet COUNT=12 EXPIRES=never CERT=e6fcad8c0e95a357d5f57accc1ee9c11
NAME=banana VERS=4.0 ID=001f5bf5b08f IDTYPE=ethernet COUNT=12 EXPIRES=never CERT=a287a6e27791de5cb88077a9d4eb87

This file locks the entire license file to the computer with this ethernet address. It serves three components, tree, banana and monkey, with twelve licenses each that can be checked out at the same time; a thirteenth checkout fails.

Once the license file has been generated for the computer, start the license manager with that file. Example:

$ sglmd -v sglmserver -f float.lic
2016/01/07 07:35:57 Server starting on localhost, port 29750, max components 64, max connections 256
Action    Component  Version  Count  Expires
Enabling  tree       4.0      10     never
Enabling  monkey     4.0      10     never
Enabling  banana     4.0      10     never
Ready...

Serving several versions of a component

One license server can serve different versions of the same component. List the lines for the same component in numerical order of version, from lowest to highest. A version 4.0 application then checks out the VERS=4.0 licenses first, before it spills over to the 5.0 licenses; in reverse order, a version 4.0 application would check out the VERS=5.0 licenses first. When version 5.0 of the software requests a 5.0 license, only 5.0 licenses are used. Example of a license file with the same component in two versions:

SERVER=localhost ID=001f5bf5b09f IDTYPE=ethernet PORT=29750
NAME=monkey VERS=4.0 ID=001f5bf5b09f IDTYPE=ethernet COUNT=12 EXPIRES=never CERT=c6bf634c55dff68e3417eeaa6abd36dfcb
NAME=monkey VERS=5.0 ID=001f5bf5b09f IDTYPE=ethernet COUNT=12 EXPIRES=never CERT=c0d918435bbfee94227888c772c948d8d3

Expired licenses

If a license expires while the license manager is running, that license is disabled. The license server checks for expired licenses once every hour, counted from the minute it was started. For each expired license, the server logs a DISABLING message; if a license was disabled for another reason, the message gives that reason.