This example evaluates an energy-saving device (ESD) by its delivered power. The ship is the Japan Bulk Carrier (JBC) at model scale with its propeller MP687. The ESD is a duct ahead of the propeller. The hull is computed in self-propulsion twice, without and with the duct. The propeller is modelled with the panel method of SHIPFLOW (PPROP).

The two computations are compared with the towing-tank tests of the National Maritime Research Institute (NMRI) of the same two configurations. The flow around the working propeller is compared with the stereo-PIV measurements of the same tests. These tests were the reference case of the Tokyo 2015 CFD workshop.

An ESD evaluation answers one question: how much delivered power does the device save, and why? The example therefore concentrates on the change between the two configurations:

  • the change of the propeller rate, the thrust, the torque and the delivered power;
  • how well the flow at the propeller is predicted;
  • how the loading of the propeller changes;
  • the mechanism by which the duct saves power;
  • the same evaluation with the lifting line of SHIPFLOW (LLINE), and the computing time of the two propeller models;
  • what the uncertainty of the measurements allows the comparison to show.

The example demonstrates the recommended set-up for such an evaluation: two single self-propulsion computations, one per configuration, with the same settings.

The JBC is a full hull form (block coefficient 0.858) with a deep wake at the stern. Its propeller works in that wake at a heavy loading. This makes it a harder case than a slender hull such as the KCS. The KCS example (Self-propulsion hybrid with complete propulsive factors: resistance, POW and self-propulsion from one file (KCS)) explains the set-up of a self-propulsion computation in general. This page explains what is different for a full hull with an ESD.

The measured case

The self-propulsion tests were made at the ship point. In such a test, the model is towed with a force equal to the skin-friction correction (SFC). The SFC is the difference in frictional resistance between the model and the ship. The propeller rate is then adjusted until the thrust of the propeller balances the rest of the resistance. The model was free to sink and trim, and it was run without a rudder.

Quantity Value Source
Scale 1 : 40 geometry
Length between perpendiculars Lpp 7.000 m geometry
Draught 0.4125 m, even keel at rest test condition
Wetted surface at rest S0, without / with ESD 12.221 / 12.270 m² test condition
Speed U 1.179 m/s (Fn = 0.142) test condition
Water fresh, ν = 1.106·10⁻⁶ m²/s (Re = 7.46·10⁶) test condition
Propeller MP687: D = 0.203 m, 5 blades, P/D = 0.75 (face pitch, constant), AE/A0 = 0.50, boss ratio 0.18, right-handed geometry
Skin-friction correction SFC, without / with ESD 18.2 / 18.1 N test condition

The measured self-propulsion points and the change the duct makes are given below. The values are those of NMRI's report of the tests (Hirata et al., in the Tokyo 2015 assessment), which gives the rate of revolution to four figures. The workshop tables round the rate to two figures, 7.8 and 7.5 1/s. That rounding alone moves the measured saving from −5.8 % to −6.0 %.

Quantity Without ESD With ESD Change
Propeller rate n (1/s) 7.810 7.516 −3.8 %
KT 0.217 0.233 +7.4 %
KQ 0.0279 0.0295 +5.7 %
Thrust T = KTρn²D⁴ (N) 22.45 22.33 −0.6 %
Torque Q = KQρn²D⁵ (N·m) 0.586 0.574 −2.1 %
Delivered power PD = 2πnQ (W) 28.76 27.10 −5.8 %
Towed resistance coefficient CT (on S0) 4.289·10⁻³ 4.263·10⁻³ −0.6 %
Effective wake wT (thrust identity) 0.448 0.519 +0.071
Open-water efficiency ηO 0.501 0.461 −8 %
Hull efficiency ηH = (1 − t)/(1 − wT) 1.457 1.684 +16 %

The values of n, KT, KQ and CT are those of NMRI. The dimensional values are derived from them with ρ = 998.93 kg/m³. The propulsive factors are derived with NMRI's open-water curve of MP687, by thrust identity.

The change of the delivered power needs neither of these. At the same speed, PD is proportional to n³KQ. The measured saving is therefore (7.516/7.810)³ · 0.0295/0.0279 − 1 = −5.8 %.

No uncertainty is given for n, KT and KQ. A change of 0.5 % in either rate moves the saving by about 1.5 percentage points (see The results against the measurement uncertainty).

What the duct does, in the measurement. The duct hardly changes the resistance (−0.6 %), so the propeller needs about the same thrust. What changes is the flow into the propeller. The wake becomes deeper (wT 0.448 → 0.519), and the hull efficiency rises by 16 %. The propeller now works at a heavier loading, and its open-water efficiency falls by 8 %. The gain is larger than the loss. The propeller turns slower, at a higher thrust and torque coefficient, and absorbs 6 % less power.

The flow. In the same tests, the velocity field around the working propeller was measured by stereo-PIV on cross-planes at the stern. It was measured without the duct (case 1.7a) and with it (case 1.8a). This example uses three of the planes:

Plane Position, from the fore perpendicular Where
S2 x/Lpp = 0.9625 ahead of the duct
S4 x/Lpp = 0.9843 between the duct and the propeller, 10 mm (0.1 R) ahead of the propeller plane
S7 x/Lpp = 1.0 (aft perpendicular) behind the propeller

S4 was measured at three blade positions, and the three are averaged here. S2 and S7 are time averages.

The propeller MP687

MP687 is a different kind of propeller from those of most other public validation cases. The propellers of the KCS (KP505), the KVLCC2 (KP458), the DTC and the PPTC are modern, wake-adapted designs. Their pitch varies over the radius, their blades are skewed, and their sections are of the NACA type. MP687 is a conventional stock propeller:

  • AU sections with a flat face. The blade sections are of the Japanese AU (MAU series) type. The pressure face is flat over most of the chord and is washed back toward the leading edge. The published pitch, 0.75 D and constant over the radius, is the pitch of the flat face. The camber and the loading are measured from another line: the line from the leading edge to the trailing edge (nose-tail line). Because of the wash-back, the pitch of this line is larger, and it varies: P/D = 0.92 at the root, 0.80 at 0.7 R and 0.75 at the tip. A blade with the published face pitch as its nose-tail pitch therefore has too little pitch. The blade that is delivered with SHIPFLOW carries the nose-tail pitch and camber. Its section shape was measured from the CAD geometry of the propeller.
  • Thick, highly cambered root sections: thickness 27 % and camber 6 % of the chord at the root, against 8 % and 2.4 % at 0.7 R.
  • Low pitch, narrow blades and little skew: AE/A0 0.50, skew about 6° at the tip, 5° rake.
  • A small model propeller at a low Reynolds number. The propeller has D = 0.203 m and turns at about 7.5 1/s. The chord Reynolds number at 0.7 R behind the hull is about 1.3·10⁵. In this range, the boundary layer on a model propeller blade is partly laminar. PPROP corrects the section lift for this automatically (Model scale Reynolds number). In this computation, the zero-lift angle of the sections is shifted by 1.1° (JBC_prop_out<n>.log in the propeller directory).
  • A deep wake and a heavy loading. The propeller works at KT ≈ 0.22 in a wake of wT ≈ 0.45, at an open-water efficiency of 0.50.

The energy-saving device

The ESD is a ring duct ahead of the propeller. A strut holds it from the hull above. The duct has a chord of 61 mm (0.30 D). It extends from 175 mm to about 117 mm forward of the aft perpendicular, so it lies ahead of the propeller plane, which is at 100 mm. Its section is set at 19.6° to the shaft. The duct therefore narrows toward the propeller, from a radius of 76 mm (0.74 R) at its leading edge to 56 mm (0.55 R) at its trailing edge.

SHIPFLOW models the duct as a body of revolution about the shaft (WSECT and ROTB). The strut is a rudder-type component (WSECT and RUDDER) attached to the duct (APPEND). Both are part of the hull definition in the command file.

Deriving the inputs

The hull is read from the model-scale IGES file (LPP=7, and ZORI=0.4125, the draught). The speed is the measured speed of the model, VSHIP(VM_S=1.179). This gives Fn = 0.1423, which the test rounds to 0.142. The hull is given at the size of the model, and nothing in the command file scales it. See Speed, size and water in the in-depth examples.

  • Water. FLUID(FRESH, TEMPERATURE=16.08) gives fresh water at 16.08 °C. Its viscosity gives the Reynolds number of the test: ν = 1.107·10⁻⁶ m²/s, within 0.1 % of the 1.106·10⁻⁶ m²/s of the test (Re = 7.46·10⁶). Its density is ρ = 998.93 kg/m³. The propeller model also takes its viscosity and vapour pressure from the temperature.
  • Propeller position and size. They are given on PROPELLER in model metres, like the hull. The workshop gives the propeller position as x/Lpp = 0.985714 from the fore perpendicular. This is 7 · (1 − 0.985714) = 0.1000 m forward of the aft perpendicular, so XSH=0.1000. The workshop gives the shaft height as 0.0404214 Lpp below the waterline. This is 0.4125 − 0.0404214 · 7 = 0.12955 m above the base line, so ZSH=0.12955. The diameter is DPROP=0.203, and the hub diameter is DHUB = 0.18 · 0.203 = 0.03654.
  • The blade. GEOFILE="MP687" is the MP687 as delivered with SHIPFLOW in data/propellers_panel/MP687. It consists of the blade description (.prda) and the section shape (.prof). Both were produced from the CAD geometry of NMRI with cad2esprep. The origin of the description is the propeller plane, where the generator line meets the shaft axis. XSH is therefore the position of the drawing as it stands (Blade geometry).
  • Towing force. The model is towed with the SFC. CTOW is this force as a coefficient on the dynamic pressure and the wetted surface of the computation. Here it was derived in three steps:

    1. Subtract the wave resistance from the SFC (next point): 18.2 − 1.90 = 16.30 N without and 18.1 − 1.90 = 16.20 N with the ESD.
    2. Take the wetted surface of the computation. XCHAP applies CTOW on this surface and prints it as _S in the _OUTPUT file: 12.4421 m² without the ESD and 12.4955 m² with it, the duct and the strut included. A short computation with the same command file gives it.
    3. Divide the towing force by the dynamic pressure times this surface. The dynamic pressure is q = ½ρU² = ½ · 998.93 · 1.179² = 694.3 Pa. This gives 16.30/(694.3 · 12.4421) = 1.8870·10⁻³ without and 16.20/(694.3 · 12.4955) = 1.8674·10⁻³ with the ESD.

    The two configurations have different wetted surfaces, so the same towing force gives a different CTOW for each. The towing force sets the thrust the propeller has to deliver. In these computations, 0.1 N of towing force moves the delivered power by about 0.6 %. - Wave resistance. The computation is a double-body RANS computation (PROGRAM(XCHAP)). It has no free surface, so it gives only the viscous resistance. In the test, however, the propeller overcomes the total resistance, including the wave resistance. The wave resistance is therefore moved into the towing force. A towing force that is smaller by the wave resistance leaves the propeller the same thrust to deliver.

    CW comes from the example Resistance with VoF, free to sink and trim (JBC): the same hull, towed at the same speed. Computed with the free surface and free to sink and trim, its resistance is 36.00 N. Computed as a double body, it is 34.10 N. The difference, 1.90 N, is the share of the free surface: the wave resistance together with the effect of the sinkage and trim. As a coefficient on the wetted surface of that example, 12.4209 m², it is CW = 0.220·10⁻³. The same wave resistance is subtracted for both configurations.

    The resistance test gives another estimate: CW = 3.6·10⁻⁴, from the measured total resistance and a form factor. The computed value is used because it belongs to the computation. The double body plus the computed CW is the resistance of the free-surface computation, 1.1 % below the measured resistance. The double body plus the CW of the test is 2.1 % above it. The choice between the two moves the delivered power by about 7 %, and it leaves the saving as it is (see How sensitive the saving is to the set-up).

The command files

examples/jbc_selfpropulsion_db_without_ESD__128GB and examples/jbc_selfpropulsion_db_with_ESD__128GB (10.9 and 13.2 million cells).

Resources: about 70 GB of memory without the duct and 80 GB with it. This is the RANS computation (65 and 76 GB) and the propeller program (4.3 GB) together. A 128 GB machine runs either. The computations were run on 24 cores and took about 1.5 to 2 hours each. Any number of cores can be used; fewer cores take longer.

Without the ESD:

xflow
  titl   ( titl="JBC without ESD, self-propulsion, PPROP (ESPPRO), Tokyo 2015 case 1.5a" )
  prog   ( xchap )
  hull   ( mono, fine )
  offs   ( iges="geometry/jbc_hull.igs", zori=0.4125, lpp=7 )
  vshi   ( vm_s=1.179 )
  fluid  ( fresh, temperature=16.08 )
  symm   ( nosym )
  self   ( on, ctow=1.8870e-3 )
  prop   ( id="JBC_prop", xsh=0.1000, zsh=0.12955, dprop=0.203, dhub=0.03654, geofile="MP687" )
end
xgrid
  size ( vfine )
end
xchap
  parallel ( nproc=24 )
  control  ( maxit=300 )
  pprop    ( id="JBC_prop", hubon, startat=150 )
end

With the ESD:

xflow
  titl   ( titl="JBC with ESD, self-propulsion, PPROP (ESPPRO), Tokyo 2015 case 1.6a" )
  prog   ( xchap )
  hull   ( mono, fine )
  offs   ( iges="geometry/jbc_hull.igs", zori=0.4125, lpp=7 )
  vshi   ( vm_s=1.179 )
  fluid  ( fresh, temperature=16.08 )
  wsect  ( id="bracket_sect", offsets="geometry/jbc_bracket_section", rmax=1.6, dimension=[200,40] )
  rudder ( id="bracket", section=["bracket_sect"], span=0.04607, s=[0,1], c=[0.03222957325,0.03222957325],
           xle=[0.02278,0.01287], origin=[0.13756,0.0,0.19020], tilt=-12.14, TP1O, TP2O, ytarget=0.15,
           dimension=[200,40,60], rmax=1.6 )
  wsect  ( id="duct_section", offsets="geometry/jbc_duct_section", origin=[0,1.25075], scale=0.060902,
           angle=-19.55, rmax=1.2, dimension=[200,60] )
  rotb   ( id="duct", sect="duct_section", dim3=51, ytar=0.1, translate=[0.17477,0,0.1296], dir=[-1,0,0],
           angle=360 )
  symm   ( nosym )
  self   ( on, ctow=1.8674e-3 )
  prop   ( id="JBC_prop", xsh=0.1000, zsh=0.12955, dprop=0.203, dhub=0.03654, geofile="MP687" )
  append ( id="bracket", adapt=["duct"], adir=3, aside=1 )
end
xgrid
  size ( vfine )
end
xchap
  parallel ( nproc=24 )
  control  ( maxit=300 )
  pprop    ( id="JBC_prop", hubon, startat=150 )
end

The two files differ only in the duct and its strut (WSECT, RUDDER, ROTB, APPEND) and in the towing force.

Why each setting

PROGRAM(XCHAP) selects the double-body RANS computation only. At this low speed, the free surface matters for the resistance but not for the flow at the propeller. For this full hull form, the potential-flow computation (XPAN) gives a wave resistance that is too small: about a third of the estimate from the resistance test. The wave resistance is therefore taken from a RANS computation with the free surface and moved into the towing force (see Deriving the inputs). The hull runs at even keel. The measured sinkage of 6 mm and trim of 0.18 % of Lpp are not modelled.

HULL(MONO, FINE), OFFSET, VSHIP, FLUID give the hull, the speed and the water; see Deriving the inputs. SYMMETRY(NOSYM): a propeller makes the flow asymmetric, so both sides of the hull are computed.

WSECT, RUDDER, ROTB, APPEND (with the ESD) give the duct and its strut, as described in The energy-saving device. APPEND(ID="bracket", ADAPT=["duct"]) joins the strut to the duct, so the grid of the strut adapts to the duct.

SELFPROPULSION(ON, CTOW=...) makes a self-propulsion computation at the towing force of the test, less the wave resistance. Nothing else is needed for the self-propulsion point. The resistance of the towed hull (CTTOT) and an open-water curve (POW) are needed only for the propulsive factors, and these are not the subject here (see Which self-propulsion set-up to use).

PROPELLER gives the position, the size and the blade of the propeller; see Deriving the inputs. JV, the advance ratio at the start, is left at its default of 0.85. The computation finds the self-propulsion point from there.

XGRID SIZE(VFINE) selects the finest of the standard grids of XGRID. The duct changes the flow in the propeller disc on the scale of its own chord, and the saving depends on resolving that. With the wave resistance of the test in the towing force, the computed saving was −4.2 % on the FINE grid and −5.9 % on VFINE (see How sensitive the saving is to the set-up).

PARALLEL(NPROC=24) runs the computation on 24 processes, with about 3 GB per process.

CONTROL(MAXIT=300) sets 300 iterations instead of the default 200. The first 150 iterations are a towed hull, before the propeller model starts (STARTAT=150, below). The next 150 are with the propeller. The delivered power settles within about 100 iterations after the propeller model starts. From iteration 250 on, it changes by less than 0.1 % (figure below).

PPROP(ID, HUBON, STARTAT=150):

  • HUBON adds the hub to the panel model of the blades. The hub follows the boss of the hull (section Hub of PPROP). The root of the blade is then loaded as on the real propeller, and the effect of the duct on the inner radii is part of what the propeller sees. The hub raises the delivered power of both configurations by about 3 %. It leaves the saving unchanged: −6.0 % without the hub and −5.9 % with it, in the computations of How sensitive the saving is to the set-up.
  • STARTAT=150 starts the propeller model after 150 towed iterations instead of the default 50. This is needed because of the duct. The reason is as follows:

    1. The propeller model samples the effective wake on a plane 0.35 R ahead of the propeller. It corrects the sampled wake for the hull wake gradient between this plane and the propeller plane (note 10 of PPROP).
    2. The correction is taken once, from the towed flow at the first run of the propeller model. It is kept for the rest of the computation.
    3. Behind a hull alone, the towed flow is developed enough for this after 50 iterations. The wake of a duct close ahead of the propeller is not. After 50 iterations, the correction at 0.66 R, in the wake of the duct, was 0.178 of the ship speed. After 150 iterations it was 0.042, and from a converged resistance computation 0.041.
    4. With the default start, the propeller saw an inflow that was too fast by 0.14 U in the wake of the duct, for the whole computation. The computed saving was then −5.0 % instead of −5.9 % (with the wave resistance of the test in the towing force; see How sensitive the saving is to the set-up).

    After 150 iterations, the correction equals that of the converged towed flow at every radius. Give a later start whenever an appendage lies close ahead of the propeller, for example a duct or a pre-swirl stator. Its wake takes longer to develop than the wake of the hull.

What is not in the command file. The defaults that matter for this case:

  • The turbulence model, EASM. With the k-ω SST model, the computed saving was about half (see How sensitive the saving is to the set-up).
  • The refinement of the hull grid around the propeller grid. PPROP refines the hull grid there by default when the propeller is behind a hull, as in the KCS examples (PPROP, note 14). Without it, the interpolation between the two grids spreads the propeller force over the long cells of the hull grid.
  • The correction of the effective wake for the hull wake gradient (NOMINAL="AUTO", note 10 of PPROP). It is taken from the towed flow of the computation itself and written to nominal_auto.dat in the propeller directory.
  • The settings for a stable self-propulsion balance behind a full stern: the relaxation of the effective wake (WRELAX=0.4), the propeller grid sized to the blade, and a run of the propeller model every 2 iterations (notes 4 and 14 of PPROP).

Propeller rate and delivered power over the iterations of the two computations, relative to their final values, settling within 0.1 % about 100 iterations after the propeller model starts at iteration 150

Results and comparison with the measurement

The results on this page were computed with SHIPFLOW 9.0.01.

Quantity Without ESD, measured computed difference With ESD, measured computed difference
n (1/s) 7.810 7.55 −3.3 % 7.516 7.22 −3.9 %
KT 0.217 0.227 +4.7 % 0.233 0.248 +6.6 %
KQ 0.0279 0.0292 +4.5 % 0.0295 0.0314 +6.4 %
T (N) 22.45 21.96 −2.2 % 22.33 21.98 −1.6 %
Q (N·m) 0.586 0.572 −2.4 % 0.574 0.564 −1.7 %
PD (W) 28.76 27.14 −5.6 % 27.10 25.60 −5.6 %
Change with the ESD Measured Computed
n −3.8 % −4.3 %
T −0.6 % +0.1 %
Q −2.1 % −1.4 %
PD −5.8 % −5.7 %

To read from it:

  1. The power saving is captured: −5.7 % computed against −5.8 % measured. The two computations use the same settings. Errors that they share, for example in the level of the resistance or of the wake, therefore cancel in the change.
  2. The thrust is within 2 % of the measurement. It follows the resistance of the self-propelled hull. Without the duct, the computed resistance in self-propulsion, with the wave resistance added, is 40.2 N. The measured value (thrust plus SFC) is 40.7 N, 1.2 % more. The propeller delivers this resistance less the towing force. The computation is at even keel, and the test was free to sink and trim.
  3. The delivered power is 5.6 % below the measurement in both configurations, and the propeller rate 3.3 and 3.9 % below.
  4. KT and KQ are 4.5 to 6.6 % above the measurement. The propeller delivers about the measured thrust at a lower rate, so it works at a heavier loading than in the test. With the thrust about 2 % and the rate 3 to 4 % below the measurement, the delivered power is 5 to 6 % below it.
  5. The level depends on the wave resistance in the towing force; the saving does not. With the estimate of the test, CW = 3.6·10⁻⁴, the delivered power is about 1.5 % above the measurement, and the saving is the same (see How sensitive the saving is to the set-up).

Where to find the results:

  • <case>_OUTPUT: n, PD, KT and KQ.
  • <case>_FORCELOG: the forces on the hull, the duct and the strut.
  • The propeller directory <case>_RUN_DIR/JBC_prop_DIR/:
    • JBC_prop_PROPLOG: the history of the balance;
    • effective.wakp and total.wakp: the effective and the total inflow over the disc;
    • panelforces.dat: the force on every blade panel over the last revolution;
    • nominal_auto.dat: the hull-gradient correction.

How the duct saves power

The resistance hardly changes. In self-propulsion, the duct carries a drag of 0.86 N (0.75 N pressure, 0.12 N friction). At the same time, the pressure resistance of the hull falls by 0.94 N, because the duct recovers pressure on the stern ahead of it. The total resistance of the self-propelled hull falls by 0.09 N, or 0.2 %. The propeller therefore delivers the same thrust (+0.1 %), as in the test (−0.6 %).

The inflow is slower where it matters. The wake of the duct reaches the propeller disc as a ring of slow flow at 0.55 to 0.75 R, the radii of the duct itself. The ring is deepest in the lower half of the disc. Inside 0.5 R, the flow is slightly faster, because it is accelerated through the duct. Averaged over the disc, the effective inflow falls from 0.496 to 0.427 of the ship speed (effective wake 0.504 → 0.573). This is the inflow in which the propeller model works: the total RANS velocity less the velocity that the propeller itself induces. It is not the thrust-identity wT of the test. Its rise, +0.069, is close to the measured rise of wT, +0.071.

Effective inflow to the propeller over the disc without and with the duct, and the change: the duct's wake as a slow ring at 0.55 to 0.75 R, deepest in the lower half, and faster flow inside 0.5 R

Circumferential mean of the effective and the total wake over the radius, without and with the duct

The same thrust from slower water costs less power. The useful power of the propeller is its thrust times its effective inflow speed. It falls by 14 %: 21.98 N at 0.427 U with the duct, against 21.96 N at 0.496 U without. The efficiency of the propeller behind the hull falls by 9 % (0.473 → 0.432), because the propeller now works at a heavier loading (KT +9.3 %). The net result is the saving: 0.861/0.913 = 0.943, or −5.7 %. In the terms of the test: the hull efficiency rises more than the propeller efficiency falls.

The propeller loading

The propeller takes its extra loading where the duct slows the inflow. The thrust coefficient per unit radius rises between 0.55 and 0.95 R, by up to 20 % at 0.7 R. It falls slightly inside 0.5 R, where the duct accelerates the flow.

Over a revolution, the thrust of one blade rises mainly while the blade passes through the lower half of the disc, from about 135° to 270°. Here the wake of the duct is deepest. (The angle is 0° at 12 o'clock and runs clockwise looking forward, with starboard at 90°.) In the upper half, the thrust barely changes. The hub panels (HUBON) keep the root loaded as on the real propeller, so the change at the inner radii is part of the comparison.

Thrust and torque per unit radius without and with the duct: the extra loading between 0.55 and 0.95 R

Thrust of one blade over a revolution, as the propeller's thrust coefficient, without and with the duct: the rise in the lower half of the disc

The blade thrust is read from panelforces.dat. This file holds the force on every panel of the five blades at each recorded step of the last revolution. The single points scatter by a few per cent from step to step. The lines are a smooth fit through them.

The flow at the propeller, computed and measured

The figures compare the axial velocity of the self-propulsion computations with the stereo-PIV measurement on the three planes. The view is looking forward, with starboard to the right.

Mean axial velocity over annuli about the shaft on the planes S2, S4 and S7, computed (lines) and measured (circles), without and with the duct

Plane Configuration 1 − U/V measured computed difference
S2 without ESD 0.568 0.559 −0.010
S2 with ESD 0.634 0.581 −0.053
S4 without ESD 0.303 0.323 +0.020
S4 with ESD 0.299 0.323 +0.024
S7 without ESD 0.017 0.021 +0.004
S7 with ESD 0.029 0.039 +0.010

The values are means over 0.2 to 1.0 R, where both have data. On S4 and S2, the measurement covers only the outer part of the disc, where the hub, the duct and the hull leave the camera a view.

  1. Behind the propeller (S7), the slipstream, its acceleration inside 0.75 R and the swirl agree with the measurement in both configurations. The mean axial velocity is within 0.010.
  2. Just ahead of the propeller (S4), the computed inflow is 0.020 to 0.024 slower than measured in both configurations. This is consistent with a propeller that turns 3 to 4 % slower than in the test and draws the flow less. Like the measurement, the computation shows almost no difference with and without the duct outside 0.7 R.
  3. Ahead of the duct (S2), without the duct, the computation agrees with the measurement. With the duct, the computed flow close to the hull at 0.5 to 0.75 R is slowed down less than measured: the measured flow almost comes to rest there, the computed flow does not. The upstream effect of the duct on the boundary layer of the hull is therefore under-predicted. Downstream, where the inflow of the propeller is set, the computation agrees with the measurement.

Axial velocity and in-plane vectors at S2, ahead of the duct, measured and computed, without and with the duct

Axial velocity and in-plane vectors at S7, behind the propeller, measured and computed, without and with the duct

The results against the measurement uncertainty

A comparison with a measurement is only as sharp as the measurement. This section collects what is known about the uncertainty of the tests, and reads the results of the example in that light.

What the test reports. NMRI gives the uncertainty of its resistance tests as 1 % of the measured value. For the self-propulsion quantities, the thrust, the torque and the rate of revolution, no uncertainty is given. The coefficients are given to three figures, and the rates to four figures in NMRI's report, 7.810 and 7.516 1/s, for its own test condition, which differs from the workshop condition by 0.3 % in resistance. The workshop tables round the rates to two figures, 7.8 and 7.5 1/s; with these the measured saving reads −6.0 % instead of −5.8 %. The rounding of a published value is itself a source of uncertainty of the same size as the measurement.

Typical uncertainties of a propulsion test. The ITTC gives a worked uncertainty analysis for a propulsion test, with a 6.5 m model at 1.7 m/s, and one for an open-water test. The values below are those of the examples. They are the level a well-equipped towing tank reaches, and they are taken here as representative, since the dynamometers of the test are not described.

Quantity Uncertainty Source
Thrust T 0.5 % calibration and acquisition of the dynamometer, propulsion test example
Torque Q 0.4 % the same
Rate of revolution n 0.5 % pulse count over the measuring time, propulsion test example
KT, KQ in self-propulsion 1.1 %, 1.0 % mostly the rate, which enters squared
KT, KQ in open water 0.7 %, 0.7 to 0.9 % open-water test example
Wake fraction wT, thrust deduction t 2 %, 5 % mean of 15 repeated runs; a single run 8 % for t
Relative rotative efficiency ηR 2 % the same
SPIV, axial velocity 2.3 % of the ship speed on average, 2.7 % at most NMRI, uniform-flow test and convergence over about 1000 images
SPIV, horizontal and vertical velocity 3.3 % and 1.2 % the same; the horizontal component suffers from the mirror alignment

The uncertainties are at the 95 % level.

What this means for the levels. The computed KT and KQ are 4.5 to 6.6 % above the measurement, the rate 3 to 4 % below it and the delivered power 5.6 % below it. These differences are several times the uncertainty of the quantities. They are differences between the computation and the test, and the sections above give their reasons: the computation at even keel, the hub, the loading at which the propeller works. The workshop found the same level in its submissions: the mean absolute error of KT and KQ was 2 to 4 % and that of the delivered power 5 to 6 %.

What this means for the saving. The saving is the ratio of two measurements made with the same equipment. The calibration errors cancel in it for the most part. What remains is the repeatability of the two runs. The saving goes as n³KQ. An uncertainty of 0.5 % in each rate gives about ±2 percentage points in the saving, and the three figures of KQ another ±0.3. The measured saving, −5.8 %, therefore carries a band of about ±2 points. The computed saving lies inside it with both propeller models: −5.7 % with PPROP and −6.4 % with LLINE. The computed changes of the thrust and the torque, +0.1 and −1.4 %, are also within the uncertainty of the measured changes, −0.6 and −2.1 %. In the workshop, the computed ratio of the delivered power with and without the duct ranged from 0.88 to 1.00 against 0.94 measured. The settings of this example are what bring the computation inside the band (see How sensitive the saving is to the set-up).

What this means for the flow. The computed mean axial velocity differs from the SPIV by 0.004 and 0.010 of the ship speed behind the propeller (S7), within the uncertainty of the measurement. Just ahead of the propeller (S4), the difference of 0.020 to 0.024 is at the uncertainty: a tendency, consistent with the lower rate, rather than an established difference. Ahead of the duct (S2), the difference of −0.053 with the duct is twice the uncertainty, and the measured change between the two configurations there, +0.066, is three times it. The comparison therefore resolves the upstream effect of the duct, and the computation under-predicts it. The scatter at the edges of the measured planes in the figures above is the measurement: the horizontal velocity of the SPIV is over-estimated by about 5 % of the ship speed near the edges of its window.

In short: the levels differ from the test by more than the measurement can explain, and the page gives the reasons. The change agrees with the test within what the measurement can resolve. For an ESD evaluation this is the useful result, and it is also its limit. A saving of a few per cent cannot be validated closer than about ±2 percentage points with rates known to 0.5 %.

How sensitive the saving is to the set-up

The settings in the command files are those that captured the saving in a set of computations of the same two configurations. All of them used PPROP with the hub. The set was computed with the wave resistance estimated from the resistance test, CW = 3.6·10⁻⁴, in the towing force. Each row differs from the next in one setting; the last row also runs at the speed of the test (below). The first three rows were started from a converged computation of the towed hull, so their hull-gradient correction is that of the developed towed flow.

Grid Turbulence model Propeller model starts CW in CTOW PD without ESD PD with ESD Saving
FINE k-ω SST developed towed flow test, 3.6·10⁻⁴ +1.5 % +5.6 % −1.9 %
FINE EASM developed towed flow test, 3.6·10⁻⁴ +0.1 % +1.8 % −4.2 %
VFINE EASM developed towed flow test, 3.6·10⁻⁴ +1.6 % +1.4 % −5.9 %
VFINE EASM iteration 50 (default) test, 3.6·10⁻⁴ +1.9 % +2.7 % −5.0 %
VFINE EASM iteration 150 test, 3.6·10⁻⁴ +1.6 % +1.5 % −5.9 %
VFINE EASM iteration 150 computed, 1.90 N (this example) −5.6 % −5.6 % −5.7 %
measured −5.8 %

PD is given as the difference from the measurement.

The rows above the last were computed at 1.1765 m/s. This is the speed of the rounded Froude number 0.142, 0.2 % below the 1.179 m/s of the test. The last row is this example, at the speed of the test. Between the last two rows, the towing force is larger by about 1.2 N. The thrust falls by 1.2 N (5.3 %), and the delivered power by 7.2 and 7.0 % in the two configurations. The saving moves by only 0.2 percentage points. The level of the delivered power follows the resistance that the propeller has to overcome; the saving does not.

  1. The turbulence model matters most. With k-ω SST, the duct saves a third of what it saves in the test, because the stern flow responds less to the duct. The effective wake by thrust identity rises by 0.036 with the duct. With EASM it rises by 0.059 on the same grid and by 0.075 on VFINE; in the test it rises by 0.071. EASM is the default of XCHAP, and the example keeps it.
  2. The grid matters next. On FINE, the computed saving is 70 % of the measured one. On VFINE, it matches. The grid has to resolve the wake of the duct in the propeller disc, a ring about a fifth of the radius wide.
  3. The start of the propeller model: see STARTAT in Why each setting.
  4. The hub changes the level, not the saving. Without HUBON, the delivered power of both configurations is about 3 % lower, and the saving is −6.0 %.

An ESD evaluation compares two computations. An error that the two share cancels in the saving. An error in how the flow responds to the device does not cancel. The set-up for an ESD is therefore chosen on the change, here against a measured saving, and not on the level of one configuration.

Panel method and lifting line

Both command files also run with the lifting line of SHIPFLOW (LLINE). In the XCHAP section, the PPROP command is replaced by:

  lline    ( id="JBC_prop", startat=150 )
  xgrefine ( on, fit, level=[1,1,2], linear )
  • STARTAT=150 starts the lifting line at the same iteration as PPROP.
  • XGREFINE refines the hull grid around the propeller. PPROP does this by default behind a hull.
  • The lifting line has no model of the hub. PPROP models the hub (HUBON).
Quantity Without ESD: measured PPROP LLINE With ESD: measured PPROP LLINE
n (1/s) 7.810 7.55 7.27 7.516 7.22 7.01
KT 0.217 0.227 0.247 0.233 0.248 0.265
KQ 0.0279 0.0292 0.0298 0.0295 0.0314 0.0312
T (N) 22.45 21.96 22.14 22.33 21.98 22.05
Q (N·m) 0.586 0.572 0.543 0.574 0.564 0.528
PD (W) 28.76 27.14 24.81 27.10 25.60 23.23
Change with the ESD Measured PPROP LLINE
n −3.8 % −4.3 % −3.6 %
T −0.6 % +0.1 % −0.4 %
Q −2.1 % −1.4 % −2.8 %
PD −5.8 % −5.7 % −6.4 %
Drag of the duct (N) 0.86 0.84
Change of the pressure resistance of the hull (N) −0.94 −1.02
Change of the disc-mean effective wake (wT +0.071) +0.069 +0.066

To read from it:

  1. Both models capture the saving, by the same mechanism. The lifting line gives −6.4 %, PPROP −5.7 %, and the test −5.8 %. In both computations, the drag of the duct is balanced by a lower pressure resistance of the hull. The effective wake rises by 0.066 to 0.069 (see How the duct saves power). The level of the effective wake differs between the two models, because each model removes its own induced velocity from the flow. The change with the duct is what compares.
  2. The thrust is the same with both models, within 1 %. It follows the resistance of the self-propelled hull.
  3. The lifting line gives this thrust at a lower propeller rate. KT is 14 % above the measurement (PPROP: 5 to 7 %). The rate is 3 to 4 % lower than with PPROP, and the delivered power 9 % lower: 14 % below the measurement (PPROP: 5 to 6 %). For the KCS propeller, the two models agree within 2 % (Self-propulsion hybrid, the self-propulsion point only (KCS)). The difference is in the propeller. MP687 is unusual among propellers (see The propeller MP687): AU sections with a flat face, a pitch that is published for that face, thick and highly cambered root sections, and a low Reynolds number. The lifting line reduces the blade to its radial distributions and a standard section behaviour. With its default settings, it does not capture such a propeller; with settings adapted to it, it comes closer (Korkmaz 2015). The panel method meshes the blade as it is, so the flat face, the pitch along the nose-tail line and the root sections are in the computation, and it corrects the section lift for the Reynolds number and models the hub (HUBON, about 3 % of the delivered power, see How sensitive the saving is to the set-up). With its default settings, it is within 5 to 6 % of the measurement.
  4. The lifting line takes less computing time. With the duct, the two computations ran one after the other on the same machine, on 24 cores, for 300 iterations each. PPROP took 1 h 15 min and LLINE 1 h 04 min, 15 % less. The time per iteration of the RANS solver is the same (13.0 and 12.9 s). The difference is the 76 runs of the panel method, about 8 s each and 10 minutes in all. One run takes about as long as for the KCS propeller.

For an ESD evaluation, the lifting line gives the saving within one percentage point of the test, in 15 % less computing time. The panel method gives the level of the delivered power closer to the test, and the loading of the blades over the revolution (see The propeller loading).

References

  • Tokyo 2015 Workshop on CFD in Ship Hydrodynamics, JBC geometry and test cases 1.5a and 1.6a (self-propulsion without and with ESD), 1.7a and 1.8a (stereo-PIV with the working propeller, without and with ESD), NMRI.
  • Hirata, N.: JBC test data in NMRI, Tokyo 2015 Workshop on CFD in Ship Hydrodynamics.
  • Hino, T., Stern, F., Larsson, L., Visonneau, M., Hirata, N., Kim, J. (eds.): Numerical Ship Hydrodynamics: An Assessment of the Tokyo 2015 Workshop, Lecture Notes in Applied and Computational Mechanics 94, Springer, 2020. The chapter by Hirata et al. gives the JBC measurements and the uncertainty of the SPIV; the chapters on self-propulsion give the statistics of the submissions.
  • ITTC Recommended Procedures and Guidelines 7.5-02-03-01.2: Uncertainty Analysis, Example for Propulsion Test, revision 01, 2017; and 7.5-02-03-02.2: Uncertainty Analysis, Example for Open Water Test, revision 01, 2014.
  • Korkmaz, K. B.: CFD Predictions of Resistance and Propulsion for the JAPAN Bulk Carrier (JBC) with and without an Energy Saving Device, Master's thesis X-15/334, Chalmers University of Technology, Gothenburg, 2015 (the lifting line of SHIPFLOW on MP687 in open water and behind the hull), https://publications.lib.chalmers.se/records/fulltext/219361/219361.pdf.