POW tip-vortex and face cavitation inception bucket (PPTC)¶
This example computes the cavitation inception bucket of the propeller VP1304 of the Potsdam Propeller Test Case (PPTC), and compares it with the measurement. The bucket is the inception cavitation number over the whole range of loadings of the cavitation-tunnel test. On its heavy side, the tip vortex cavitates first. On its light side, the pressure side (face) of the blade cavitates first.
SVA Potsdam measured the propeller in its K15A cavitation tunnel. Besides the open-water curves and the sheet-cavitation observations, SVA published two kinds of inception data:
- the cavitation number at which the tip vortex starts to cavitate, at six loadings, on two blades;
- at the lightest loadings, the cavitation number at which the pressure side starts to cavitate.
These are quantitative data, and a computation can be checked against them point by point.
The example demonstrates the recommended set-up for an inception computation:
- one
POWcomputation over the advance ratios of the test, at the constant rate of revolution of the test (FIXN); - the hub and cap of the tunnel (
HUBFILE); PPROPon its defaults;- the cavitating evaluation made once per advance ratio, as a post-evaluation (
POST); - both inception criteria switched on: the tip vortex (
TIPVORTEX) for heavy and moderate loading, and the face (FACECAV) for light loading.
The whole bucket comes out of one computation, in one file. The same evaluation also gives the sheet cavity. At the end of the page, this is shown for one of the published sheet-cavitation cases.
The measured inception¶
The inception tests were run in uniform inflow at a constant rate of revolution, n = 25 1/s. At each advance ratio, the tunnel pressure was lowered until the tip vortex started to cavitate. The report defines inception as the point where a cavitating tip vortex is present for about 5 % of the observation time. The cavitating vortex starts behind the blade tip, and it comes closer to the tip as the pressure falls.
| Quantity | Value | Source |
|---|---|---|
| Diameter D | 0.250 m | geometry |
| Hub | the tunnel's shaft, hub and cap, 0.305·D at the blades | test set-up |
| Rate of revolution n | 25 1/s | test condition |
| Water | 22.8 °C, ρ = 997.54 kg/m³, ν = 9.425·10⁻⁷ m²/s | test condition |
| Advance ratio | Jc, corrected for the tunnel walls (Glauert) | report |
| Jc | Measured KT, blade 1 / blade 3 | Tip-vortex inception σn, blade 1 / blade 3 | Mean of the two blades |
|---|---|---|---|
| 0.865 | 0.447 / 0.448 | 6.62 / 6.62 | 6.62 |
| 0.973 | 0.387 / 0.388 | 4.23 / 4.73 | 4.48 |
| 1.081 | 0.329 / 0.331 | 3.09 / 3.34 | 3.21 |
| 1.188 | 0.263 / 0.274 | 1.99 / 2.34 | 2.16 |
| 1.285 | 0.223 / 0.214 | 2.91 / 2.16 | 2.54 |
| 1.343 | 0.187 / 0.184 | 2.34 / 2.21 | 2.27 |
| 1.497 | 0.107 / 0.103 | – (pressure-side sheet 8.34 / 6.04) | 7.19 |
The advance ratios are the corrected ones, Jc. At Jc, the propeller gives the same thrust in unbounded flow, and the computation is made in unbounded flow.
Each blade was observed separately. At the same loading, the two blades differ by up to a third. The mean of the two blades is the reference here.
The inception cavitation number falls with the loading down to Jc ≈ 1.2, and then it rises again. This gives the bucket its name. At light loading, the blade tip is loaded on its pressure side, and the vortex then starts from the pressure side. At the light end of the test, the pressure side of the blade cavitates first. At Jc = 1.340, a pressure-side sheet starts at σn = 2.93 / 2.97 (blade 1 / 3). This is above the tip-vortex inception at that loading, which was observed at Jc = 1.343. The two loadings differ by 0.003, and the tables of this page list both under 1.343. At still lighter loading, only the pressure-side sheet is reported. The seventh condition of the example is the lightest of the test, Jc = 1.497. There, the two blades differ by a third (8.34 against 6.04).
The conditions and the measured inception are published in SVA Potsdam report 3753 (Heinke, 2011).
Deriving the inputs¶
Everything in the command file follows from the test conditions, with one step in between: the loading is matched by thrust, not by advance ratio.
- Advance ratio: equal thrust. Inception follows the loading of the blade tip. The computation must therefore carry the measured thrust. At the measured Jc, the computed open-water thrust differs from the measured one: by up to 8 % at the lighter loadings here, and by 12 % at the lightest. The computation is therefore run at the advance ratios where its KT without cavitation equals the measured one (the mean of the two blades). This is thrust identity. The advance ratios are read off a computed open-water curve of the same set-up: the curve of POW in a cavitation tunnel at fixed n with the tunnel's hub and cap: panel method and lifting line (PPTC). That curve was computed with the same hub, water and rate of revolution. For the first condition, the advance ratio is J = 0.8534.
- Rate of revolution. The tunnel holds n = 25 1/s, and
POWwithFIXNdoes the same. Each advance ratio is computed at the speed J·n·D. The speed onVSHIPis that of the first advance ratio,JV=0.8534: VA = 0.8534 · 25 · 0.250 = 5.3338 m/s, given asVSHIP(VM_S=5.3338). - Size. The propeller is given at its size in the tunnel,
DPROP=0.250. Nothing in the command file scales it (noOFFSET,SCALEorREFLEN). Do not addSCALEorREFLEN. With a speed in m/s, they scale the speed by Froude's law, as for a ship drawn at full scale. See Speed, size and water in the in-depth examples. - Reynolds number. At the first advance ratio, VA·D/ν = 5.3338 · 0.250/9.388·10⁻⁷
= 1.420·10⁶. The log of the computation prints it as
Re_D. The viscosity 9.388·10⁻⁷ m²/s is the value SHIPFLOW takes for fresh water at 22.8 °C, 0.4 % below the 9.425·10⁻⁷ m²/s of the report, so the Reynolds number is 0.4 % higher. - Water.
FLUID(FRESH, TEMPERATURE=22.8)gives the water temperature of the test. The temperature sets the density, the viscosity and the vapour pressure. To use the values of the report exactly, giveFLUID(FRESH, TEMPERATURE=22.8, DENS=997.54, VISC=9.425e-7). KeepTEMPERATURE: the propeller model takes its viscosity and vapour pressure from it. - Cavitation number.
SIGMAN=7.0is one value for all seven advance ratios. It is above every measured tip-vortex inception. The inception criteria are evaluated on the blade loading. The computed inception cavitation number therefore does not depend on the value given, as long as no sheet cavity forms that changes the loading. A cavitation number above the inception range keeps the blade (nearly) free of cavitation at every condition. The result is the margin to inception at that cavitation number. The inception cavitation number isSIGMANminus the margin. - Hub.
HUBFILEgives the shaft, the hub and the cap of the tunnel as a contour file. It is the same file as in POW in a cavitation tunnel at fixed n with the tunnel's hub and cap: panel method and lifting line (PPTC).DHUB=0.07625is the hub diameter at the blades, 0.305·D. On a hub this large, the hub belongs in the computation.
The seven advance ratios:
| Jc | Measured KT (mean) | J at equal thrust | Computed KT at that J |
|---|---|---|---|
| 0.865 | 0.448 | 0.8534 | 0.450 |
| 0.973 | 0.387 | 0.9705 | 0.389 |
| 1.081 | 0.330 | 1.0858 | 0.332 |
| 1.188 | 0.268 | 1.2106 | 0.270 |
| 1.285 | 0.218 | 1.3101 | 0.219 |
| 1.343 | 0.186 | 1.3695 | 0.187 |
| 1.497 | 0.105 | 1.5197 | 0.105 |
The command file¶
The command file is examples/pptc_pow_tipvortex_bucket.
Resources: about 41 GB of memory: about 28 GB for the RANS computation with the hub and 24
processes, and up to 13 GB for the propeller program during the tip-vortex evaluation. A workstation
with 64 GB is enough. The results on this page were computed with 24 processes (PARALLEL(NPROC=24)).
The seven advance ratios took about 30 minutes. Any number of cores can be used; fewer cores take
longer.
xflow
titl ( titl="PPTC VP1304 tip-vortex inception bucket, SVA 3753" )
prog ( xcha )
hull ( pow )
fluid( fresh, temperature=22.8 )
vshi ( vm_s=5.3338 )
prop ( id="VP1304", dprop=0.250, dhub=0.07625, jv=0.8534, geofile="VP1304", hubfile="VP1304_tunnel" )
end
xchap
parallel ( nproc=16 )
pow ( on, j=[0.8534,0.9705,1.0858,1.2106,1.3101,1.3695,1.5197], output="POW_VP1304.dat", fixn )
pprop ( id="VP1304", post, cavitation, tipvortex, facecav, sigman=7.0 )
end
Why each setting¶
HULL (POW) and POW (ON, J=[…], FIXN) set up an open-water computation in a box
domain around the propeller. The seven advance ratios of equal thrust are computed one after the other,
at the constant rate of revolution of the tunnel. At each advance ratio, the iterations stop when
KT and KQ have settled, that is when they change by less than 0.1 % between two
propeller runs.
POST, CAVITATION, SIGMAN=7.0: during the iterations, the propeller runs without cavitation, and
only its time-averaged force enters the flow computation. When the iterations at an advance ratio
have finished, the propeller is evaluated once more on the converged flow. This evaluation is
cavitating, at the given cavitation number, and the inception criteria run with it (see note 5 of
PPROP).
TIPVORTEX gives the tip-vortex inception margin (note 9 of
PPROP). The model compares the suction in the
core of the vortex that the blade sheds with the cavitation number, at every blade angle. With
TIPVORTEX, the evaluation steps at 2°, as the vortex needs. This is the part of the computation
that needs the memory. It therefore belongs in a POST evaluation, not in every propeller run.
FACECAV gives the face (pressure-side) cavitation inception margin (note 15 of
PPROP). At light loading, the vortex starts
from the pressure side of the tip. The tip-vortex model does not represent this, so the face
criterion covers that side of the bucket. Neither criterion does anything without CAVITATION.
HUBFILE gives the hub and cap of the tunnel, derived above.
FLUID (FRESH, TEMPERATURE), VSHIP (VM_S), JV give the water and the speed of the first
advance ratio, derived above. FIXN takes the speed of the others from J.
What is not in the command file. Everything else is a default of PPROP. The defaults are
chosen for any propeller, not for this one:
- The propeller grid and the sampling planes are sized to the blade (note 14 of PPROP).
- The leading-edge vortex correction.
PPROPdecides it from the Reynolds number. It is on at model scale. - The core factor of the tip-vortex model and the factor of the face criterion keep their calibrated defaults. The iteration of the cavity shape keeps its defaults too (see the notes of PPROP). Nothing has to be tuned for a new propeller.
Results and comparison with the measurement¶
The results on this page were computed with SHIPFLOW 9.0.01.
Next to the open-water table POW_VP1304.dat, the computation writes POW_VP1304_TVC.dat. It has
one row per advance ratio with:
- J and KT without cavitation;
- the tip-vortex inception margin
TVCMat the given cavitation number; - the share of the revolution with a cavitating vortex,
TVCS, at the given cavitation number; - the tip-vortex inception cavitation number σi =
SIGMAN−TVCM; - the face inception cavitation number.
The same values are in the _OUTPUT file of each advance ratio (note 9 of
PPROP). The inception of the propeller is the
larger of the two inception cavitation numbers.
| Jc | Measured σi (mean of two blades) | Computed σi, tip vortex | Computed σi, face | Larger of the two | Difference |
|---|---|---|---|---|---|
| 0.865 | 6.62 | 6.00 | – | 6.00 | −9 % |
| 0.973 | 4.48 | 4.68 | – | 4.68 | +4 % |
| 1.081 | 3.21 | 3.55 | – | 3.55 | +10 % |
| 1.188 | 2.16 | 2.47 | 1.32 | 2.47 | +14 % |
| 1.285 | 2.54 | 1.75 | 2.20 | 2.20 | −13 % |
| 1.343 | 2.95 (pressure-side sheet) | 1.36 | 3.04 | 3.04 | +3 % |
| 1.497 | 7.19 (pressure-side sheet) | 0.62 | 5.97 | 5.97 | −17 % |
At the three heaviest loadings, the face does not cavitate at any cavitation number in the range of the test: the computed face values are below 0.3. At the two lightest loadings, the measured reference is the pressure-side sheet. There, the sheet starts at a higher cavitation number than the tip vortex: 2.93 / 2.97 (observed at Jc = 1.340) against 2.34 / 2.21 at 1.343, and 8.34 / 6.04 with no tip-vortex event at 1.497.
The figure shows the inception cavitation number against the corrected advance ratio of the test. The black circles and squares are the measured tip-vortex inception on blade 1 and blade 3. The grey triangles are the measured inception of the pressure-side sheet. The blue line is the computed tip-vortex inception, and the orange line is the computed face inception, both with the hub of the tunnel. The thin dashed lines are the same computations without the hub.
How to read it:
- The bucket. The measured inception falls from 6.6 to 2.2 as the loading falls. At light
loading it rises again, steeply: at Jc = 1.497 the face cavitates at σn = 6
to 8. The computation follows both sides:
- The tip-vortex criterion follows the heavy side, within −10 to +14 %.
- The face criterion takes over between Jc = 1.19 and 1.29, and it follows the light side. At the next two conditions it is within −13 and +3 %.
- At the lightest condition, the face criterion is 17 % below the mean of the two blades. There, the blades themselves differ by a third, and the computed 5.97 is within 2 % of the 6.04 of blade 3.
- The lowest point of the computed bucket is about 2.0, at Jc ≈ 1.26. The measured lowest point is 2.16, at Jc = 1.188. The differences are of the size of the difference between the two blades of the test.
- The margin. The model is meant for ranking. It shows how far a condition or a design is from
inception, at the loading and the cavitation number of the computation. At another cavitation
number, the margin is that cavitation number minus σi. A negative margin means that the
vortex (or the face) cavitates.
TVCSthen gives the share of the revolution in which it cavitates. - Equal thrust matters. At the measured Jc, the computed thrust is up to 8 % off at the lighter loadings and 12 % off at the lightest. The inception then shifts accordingly. This is a difference in loading, not an error of the model. Compare at equal thrust whenever a computation is checked against a tunnel test.
- The hub. The dashed lines are computed without
HUBFILE, for the first six conditions, at the advance ratios of equal thrust of the set-up without the hub. Without the hub, the computed tip-vortex inception is up to 7 % higher at heavy loading and the same at light loading. The face inception at Jc = 1.343 is 16 % higher. On a hub this large, the hub changes the radial distribution of the load. With the hub, the computation is closer to the measurement at four of those six loadings. Over those loadings, the bucket is within −13 to +14 % with the hub, against −3 to +20 % without it. - The blade stays free of a sheet. At
SIGMAN=7.0, the blade carries no sheet at six of the seven conditions. At the heaviest one, a thin leading-edge sheet covers about 2.4 % of the blade. (The test sees a suction-side sheet start at σn = 6.0 to 6.4 there.) The sheet changes the thrust by less than 0.1 %. Every blade angle is inside the range of the model (NOUT= 0), so the blade loading that the criteria read is valid. At the lightest condition, the computed face inception, 5.97, lies belowSIGMAN, so the face stays free of a cavity at σn = 7.0 in the computation. In the test, the face incepts at 7.19, aboveSIGMAN, so there it cavitates at this cavitation number (see the table). The face criterion gives the margin, not the cavity (note 15).
The computation gives the inception and nothing beyond it. The extent and the volume of a vortex cavity or of a face cavity after inception are not computed (notes 9 and 15 of PPROP). The calibration is made in uniform inflow, as here. Behind a hull, the margin can be optimistic; see note 9.
The sheet cavity as a by-product¶
At a cavitation number below inception, the same evaluation computes the sheet cavity. The published sheet-cavitation observations of this propeller are the cases of the smp'11 workshop. Case 2.3.1 has Jc = 0.9947, σn = 2.024, 23.2 °C, ρ = 997.44 kg/m³, ν = 9.337·10⁻⁷ m²/s and n = 24.987 1/s. It is run with the same command file, reduced to one advance ratio:
- at equal thrust, KT = 0.378, the measured open-water thrust at that Jc; with the hub, this is J = 0.9883;
- with
SIGMAN=2.024; - with
PLOT, which writes the blade pressure and the thickness of the sheet cavity for every recorded blade angle, as VTU files for ParaView.
The observation shows a suction-side sheet on the outer part of the blade, which merges into the tip vortex, and root cavitation.
The figure shows the computed cavity thickness on the suction side (left) and on the pressure side (right) of the blade at the 12 o'clock position.
Three things to read, in order:
- The thrust without cavitation.
POW_VP1304.datholds KT and KQ of the propeller without cavitation. KT is 0.380, within 0.5 % of the measured 0.378. - The extent of the cavity. Open
unsteady.pvdin ParaView and show the cavity thickness. Or readapscav.resfor the area per blade angle. The computed sheet covers about 12 % of the blade (ACAVin_OUTPUT). It runs along the leading edge from r/R = 0.48 to the tip. It is thickest, about 0.7 mm, around r/R = 0.8. Toward the tip it thins out. There, the observation shows the sheet merging into the tip vortex. The tip-vortex model reports this vortex as cavitating all round the revolution (TVCM= −2.47,TVCS= 100 %). The whole computed sheet is thin: about 3.5 % of the blade is covered by a cavity thicker than half a millimetre. At this condition, the 0.5 mm reading of the notes of PPROP therefore shows only a small part of the sheet. The observation shows a sheet on the outer part of the blade. Compare the extent of the whole computed sheet with the sketch of the observation. Every blade angle is in the range of the model (NOUT= 0). - The cavitating thrust.
ktkq.datholds KT and KQ of the cavitating evaluation. At this condition, the sheet changes KT by +0.1 % (DKTC). The measurement shows a loss of 1 to 2 %. With a thin partial sheet, the computed thrust rises slightly where tests show a small loss. Here, the cavitating thrust is therefore a check of consistency, not a prediction of thrust breakdown.
By design, the model does not show two things at this condition: the root cavitation (the root strip is left without cavitation) and the extent of the tip-vortex cavity (the tip vortex is reported as inception only).
References¶
- Heinke, H.-J.: Potsdam Propeller Test Case (PPTC), Cavitation Tests with the Model Propeller VP1304, Report 3753, Schiffbau-Versuchsanstalt Potsdam, April 2011: the inception tests, the open-water test in the tunnel and the observation points.
- Second International Symposium on Marine Propulsors (smp'11), Workshop: Propeller Performance, Hamburg, 2011: the sheet-cavitation observations (case 2.3) and the workshop evaluation.